- Network Converter for Controlled Motors NETC01-M3
-
Slave 스테핑 모터
-
MECHATROLINK Spec
M-II M-III M-4
ORIENTAL MOTOR Co.,Ltd.Updated on:Jan 6, 2022
NETC01-M3 converts MECHATROLINK-Ⅲ communication protocol to RS-485 communication protocol.
With NETC01-M3, you can transparently control up to 16 of our RS-485 products by Standard I/O commands from a MECHATROLINK-Ⅲ master.
In addition to stepping motors, wide variety of products such as sliders, cylinders, and blushless motors will be able to connect to NETC01-M3 in the future.
NETC01-M3
DownloadSpecifications
Item | Specifications | |||||
---|---|---|---|---|---|---|
Baud Rate | 10Mbps | |||||
Communication Cycle | 0.5ms / 1.0ms / 1.5ms / 2.0ms / 2.5ms / 3.0ms / 3.5ms / 4.0ms / 8.0ms | |||||
Station Address | 03h to 0EFh | |||||
Corresponding Profile | MECHATROLINK-Ⅲ I/O M-Ⅲ standard | |||||
RS-485 Communication Specification |
Electric characteristics | In conformance with EIA-485 | ||||
Baud Rate | 625kbps | |||||
Physicallayer | Asynchronous mode (8 bits, 1 stop bit, no parity) | |||||
Protocol | GW Protocol Ver.2 (Open protocol established by ORIENTAL MOTOR Co.,Ltd.) | |||||
Connection pattern | 16 units Max. |
MECHATROLINK specifications
M-Ⅲ | |
---|---|
Profile | Standard I/O |
Data size | 16, 32, 48, 64byte |
Transmission cycle | 0.5ms, 1.0ms, 1.5ms, 2.0ms, 2.5ms, 3.0ms, 3.5ms, 4.0ms, 8.0ms |
Contact Information
ORIENTAL MOTOR CO.,Ltd.
4-8-1 Higashiueno,Taito-ku,Tokyo 110-8536 Japan TEL: +81-3-6744-0351 FAX: +81-3-5826-2575 |