| Item |
Specifications |
| MECHATROLINK communications |
Protocol |
MECHATROLINK-Ⅲ |
| Baud Rate |
100Mbps |
| Transmission cycle |
0.5ms, 1.0ms, 2.0ms, 4.0ms |
| Communication cycle |
0.5ms to 32ms (increments of 0.5ms) |
| Node address |
03h to EFh (initial value: 03h)
※AS for the master controller, extended address-compliant is required. |
| Command method (Operation function) |
Interpolation feed (INTERPOLATE), Positioning (POSING), Constant-speed feed (FEED), Positioning at Constant-speed by external input (EX_FEED), Positioning by external input (EX_POSING), Return-to-home (ZRET) |
| Monitor |
Command position, Command speed, Feedback position, Feedback speed, Alarm code, Status of driver |
| I/O signals |
Input signal |
Input: 4 points (Signal allocation can be changed)
Forward drive prohibition Input (FW-BLK), Reverse drive prohibition Input(RV-BLK), Homing deceleration switch Input (DEC), Latch Input1 (EXT1) |
| Output signal |
Output: 3 points (Signal allocation can be changed)
Alarm Output (ALM-B), Driver ready completed Output (READY), Motor operating Output (MOVE) |
| Power supply |
Main power supply |
DC24V±10% or DC48V±10%
Power supply current capacity: 7.0A |
| Control power supply |
DC24V±10%
Power supply current capacity 2-axis: 1.0A, 3-axis: 1.25A, 4-axis: 1.5A |
| Operating ambient temperature and humidity |
Ambient temperature : 0 to+50°C (+32 to +122°F) (non-freezing)
Humidity: 85% or less (non-condensing) |