Low Harmonics Regenerative Matrix Converter U1000

变频驱动器

Power Regeneration to Save Energy!
Generate electric power when rotate the motor and achieve energy saving with utilizing the energy efficiently.__RCMS_CONTENT_BOUNDARY__Low Harmonics!
Achieve the less harmonic since the sinusoidal input current is the almost same as commercial power supply.
Also, correspond to downsizing of the power supply capacity as well as Harmonic Suppression Guidelines easily.__RCMS_CONTENT_BOUNDARY__Compact All-in-One Unit!
Harmonic countermeasures that were previously required to connect a converter, such as input AC reactors, harmonic filter reactors, and capacitors, are not necessary, which helps you save wiring, space, and energy costs.__RCMS_CONTENT_BOUNDARY____RCMS_CONTENT_BOUNDARY____RCMS_CONTENT_BOUNDARY____RCMS_CONTENT_BOUNDARY____RCMS_CONTENT_BOUNDARY____RCMS_CONTENT_BOUNDARY____RCMS_CONTENT_BOUNDARY__

Item Specifications
Rated
Input/Output
Max. Output Voltage Depends on input voltage
Max. Output Frequency 400 Hz
Power Supply
Characteristics
Rated Voltage/
Rated Frequency
Three-phase AC power supply 200 V Class: 200 to 240 Vac 50/60 Hz, 400 V Class: 380 to 480 Vac 50/60 Hz
Allowable Voltage Fluctuation −15% to+10%
Allowable Frequency Fluctuation ±3% (Frequency fluctuation rate: 1 Hz/100 ms or less)
Allowable Power Voltage Imbalance between Phases less than 2%
Control
Characteristics
Control Method Sine-wave PWM [V/f control, V/f Control with PG, Open Loop vector control, Closed Loop Vector Control, Open Loop Vector Control for PM, Advanced Open Loop Vector Control for PM, Closed Loop Vector Control for PM (switched by parameter setting)]
Harmonic Current Distortion Rate 5% or less (IEEE 519)
Input Power Factor 0.98 or more (for rated load)
Overload Tolerance HD Rating: 150% of rated output current for 60 s, ND Rating: 120% of rated output current for 60 s (Derating may be required for repetitive loads)
Status Output 1 C-relay output at failures, 1 a contact output (multi-function) during operation, 2 multi-function PHC outputs selectable at alarms, 2 multi-function analog outputs selectable for analog outputs, Pulse train output: 1 (multi-function)