YASKAWA ELECTRIC CORPORATIONUpdated on:Apr 4, 2019

U1000 is the product applies matrix converter technology for the first time in the world.
It wipes out the existing system problems in harmonic measures and power regeneration, also contribute to the customers with energy-saving performance more than conventional inverter.
The U1000 was awarded the Minister's Prize of the Economy, Trade and Industry in 2015 which is the highest award in the Energy Conservation Grand Prize.

  • Power Regeneration to Save Energy!
    Generate electric power when rotate the motor and achieve energy saving with utilizing the energy efficiently.
  • Low Harmonics!
    Achieve the less harmonic since the sinusoidal input current is the almost same as commercial power supply.
    Also, correspond to downsizing of the power supply capacity as well as Harmonic Suppression Guidelines easily.
  • Compact All-in-One Unit!
    Harmonic countermeasures that were previously required to connect a converter, such as input AC reactors, harmonic filter reactors, and capacitors, are not necessary, which helps you save wiring, space, and energy costs.

U1000

Download

Specifications

Item Specifications
Rated
Input/Output
Max. Output Voltage Depends on input voltage
Max. Output Frequency 400 Hz
Power Supply
Characteristics
Rated Voltage/
Rated Frequency
Three-phase AC power supply 200 V Class: 200 to 240 Vac 50/60 Hz, 400 V Class: 380 to 480 Vac 50/60 Hz
Allowable Voltage Fluctuation −15% to+10%
Allowable Frequency Fluctuation ±3% (Frequency fluctuation rate: 1 Hz/100 ms or less)
Allowable Power Voltage Imbalance between Phases less than 2%
Control
Characteristics
Control Method Sine-wave PWM [V/f control, V/f Control with PG, Open Loop vector control, Closed Loop Vector Control, Open Loop Vector Control for PM, Advanced Open Loop Vector Control for PM, Closed Loop Vector Control for PM (switched by parameter setting)]
Harmonic Current Distortion Rate 5% or less (IEEE 519)
Input Power Factor 0.98 or more (for rated load)
Overload Tolerance HD Rating: 150% of rated output current for 60 s, ND Rating: 120% of rated output current for 60 s (Derating may be required for repetitive loads)
Status Output 1 C-relay output at failures, 1 a contact output (multi-function) during operation, 2 multi-function PHC outputs selectable at alarms, 2 multi-function analog outputs selectable for analog outputs, Pulse train output: 1 (multi-function)

MECHATROLINK specifications

  M-Ⅰ M-Ⅱ
17-byte 17-byte 32-byte
Command Inverter × × ×
Transmission cycle =Comm. Cycle 2ms 500μs to 8ms 1ms to 8ms
≠Comm. Cycle 2ms to 8ms
 
  M-Ⅲ
Profile Standard Inverter
Data size 32byte, 48byte
Transmission cycle 0.250ms to 8ms